Pipette Calibration and Service from Pipette.com
OUR PIPETTE.COM CALIBRATION FACILITY
Pipette.com is an ISO 17025 Accredited Calibration Facility that calibrates and repairs all pipette brands and models. As an ISO 17025 and FDA Registered Facility, you can rest assured that the most qualified technicians are servicing your pipettes. All of the Pipette Calibration Services take place in a controlled environment, where the highest quality NIST traceable 5, 6, and 7 place Mettler-Toledo balances with up to 0.0000001g sensitivity are being utilized to calibrate pipettes. We are the largest independent pipette calibration facility on the West Coast, which allows us to offer quick turnaround times for calibration (24-48 hours is standard) and free estimates on repairs.
|
|
|
Verification
|
Calibration
|
Calibration Plus
|
Is This Right For My Lab?
|
1. Are there new pipettes that require a calibration due date? 2. Do you need to demonstrate your pipettes are within manufacturer specifications in between calibration cycles? |
1. Do you want to extend the longevity of your pipettes? 2. Are your pipettes routinely utilized in the laboratory?
|
1. Do you verify your pipettes in the lab in between calibration cycles? 2. Is your laboratory a GLP, CLIA, manufacturing, or audited laboratory? 3. Are you obtaining odd results that could be attributed to incorrect volumes? |
Calibration Overview
|
Pipettes are confirmed to be within or out of manufacturer’s specifications in an environmentally controlled facility. |
Pipettes undergo preventive maintenance (PM) and calibrated to manufacturer specifications. |
Pipettes undergo verification first, and then preventive maintenance (PM) and calibration. |
Benefits
|
Pipettes are confirmed to be within or out of manufacturer’s specifications. This is also a cost-effective way to obtain a calibration due date on new pipettes. |
Preventative maintenance (PM) proactively replacing parts that are known to fail before they affect the performance of the pipette. Many pipettes that are out of tolerance fail because PM parts have worn out. |
You can demonstrate your pipettes are within calibration range before they undergo preventative maintenance and calibration. Alternatively, if your pipettes are out of tolerance, you can adjust future calibration intervals to be closer together. |
Pipette Verification - Pipettes undergo a Leakage Test, Functional Test, and Calibration Check are performed with 4X2 weighings
Preventative Maintenance- Each pipette is completely dissembled, cleaned inside & out, pistons are polished & re-greased, and seals &/or o-rings are replaced as needed (as specified by the manufacturer, make, & model) then reassembled. Parts that can wear-out are proactively replaced.
Online Data Reports Retrieving & Pipette Management Tool - Instantly access a pipette's history, calibration reports and calibration due date on line with our free pipette management tool.
Pipette Calibration - Every pipette undergoes 4x2 weighings (2 at low volume & 2 at high volume as specified by manufacturer requirements) in an environmentally controlled calibration facility. Extended calibration points & weighings, and individual channel calibration for multichannel pipettes are available upon request.
|
Complimentary Paper Report - Each Report provides detailed pipette information, mean, standard deviation, and variance of weighings, pipette performance status listed as Pass/ fail, lab conditions during the calibration process, list of parts used in repair, computer-generated barcode linking to online report.
Calibration Label - Every serviced pipette receives a calibration or verification sticker with a scannable barcode and comprehensive information including the calibration date, next calibration due date, and serial number. Optional information such as user, equipment number and location can also be included on the label.
Automated Email Reminders for Your Next Calibration Service Date - You can choose to be notified via email 4 weeks to 6 weeks before the pipette calibration due date.
|
3rd Point Reading (per channel) Median point (4 weighings) can be added to any calibration order.
Extended 10×2 Readings (per channel) Extended Measurements takes 10 measurements at 2 data points (10×2) to provide more statistical data compared to the 4×2 weighings.
Multi-Channel Readings (per channel) Each channel of the multichannel pipette is individually adjusted, weighed, and calibrated. Recommended for precise, quantitative work.
DNA/RNA Decontamination Removes existing DNA and RNA contamination, such as over aspirated oligonucleotides.
|
Printed Copy of GMP/ GLP Calibration Report* Includes all of the features of the complimentary report plus the individual weighings in addition to the mean, a dedicated certificate for each pipette, detailed information on the equipment utilized by Pipette.com, and detailed technician information.
48 Hour Service**
2 Business day pipette calibration turn-around
24 Hour Service** 1 Business day pipette calibration turn-around is available for $5 per pipette
|
Frequently Asked Questions
What is pipette calibration?
It is a process of examining and/or adjusting the pipettes to the true value by comparison to the standard which is set by the manufacturer of that said pipette. The standard in this case is the pipetting range set by the pipette manufacturer to be accurate and precise at low volume and high volume of the pipette. At Pipette.com, we perform metrology based pipette calibration; Metrology based pipette calibration provides a platform where the process is done within strict guidelines of National Institute of Standards and Technology (NIST). This ensures that there is a methodology and a standard set for all of the equipment used to calibrate the pipettes.
Why is metrology based pipette calibration important?
Metrology is defined as a science of measurement. Metrology based pipette calibration provides a platform where the process is done within strict guidelines of National Institute of Standards and Technology (NIST). This ensures that there is a methodology and a standard set for all of the equipment used to calibrate the pipettes. If this standard is not followed there cannot be a statistical guarantee that your results are accurate to true standards. Science is based on reproducible results. When reproducible results cannot be achieved all work is voided. Thus, scientists must strive that all of their work is reproducible. In order to achieve reproducibility scientists must have accurate and precise equipment. Pipettes are the cornerstone of all research, thus they must always be precise and accurate. In order to achieve this scientists must choose pipette service providers that follow strict metrology guidelines. Providers whose equipment is also calibrated and follows strict NIST rules can provide accurate and precise results giving you informative data on the status of your work and your pipette. Without metrology based calibration one cannot statistically say if the pipette is truly within range, it is simply an assumption using an uncertified piece of equipment.
Are your technicians trained by manufacturers?
Yes, our technicians are trained by manufacturers and receive on-going training
What brands of pipettes do you repair & calibrate?
Here is a list of the most popular bands for pipette repair and pipette calibration, we can service any pipette brand even if it is not listed below.
• Accupet
• Biohit
• BrandTech
• CAPP
• Cole-Palmer
• Drummond
• Eppendorf
• Labnet
• Matrix
• Nichiryo
• Oxford Lab Products
|
• Rainin
• Sartorius
• Socorex
• Falcon
• Gilson
• Hamilton
• Heathros
• Hirschmann
• Integra Bioscience
• Jencons
|
|
|
What types of pipettes do you repair & calibrate?
- Single channel manual pipettes and electronic pipettes
• Multichannel manual pipettes and electronic pipettes
(8-channel pipettes, 12-channel pipettes, 16-channel pipettes and the less common 4-• channel pipettes, 6-channel pipettes, 48-channel pipettes, 64-channel pipettes, and 96-channel pipettes too)
• Positive displacement pipettes
• Repeaters
• Bottletop dispensers
• Burettes
• Motorized controllers
Can you calibrate Rainin pipettes? - why this question? should we keep this?
Yes, we can calibrate Rainin pipettes and repair Rainin pipettes.
Do you repair Pipet-Aids?
Yes, we can repair Pipet-Aids and motorized controllers.
What is preventative maintenance (PM)?
Preventative Maintenance (PM) is a step in the calibration process that greatly enhances the longevity of your instrument. PM includes full disassembly, interior & exterior cleaning, piston polishing & re-greasing, and new seals/o-rings are replaced as needed. An in-depth PM process helps keep your pipettes operating at peak performance in between your regularly scheduled calibration service dates.
Do you perform calibration on site?
No, we do not offer any onsite services due to limited control of environmental conditions (i.e. temperature, humidity, air flow, and direct sunlight) and use the proper equipment (ultra-micro balances situated on marble tables). The American Association for Laboratory Accreditation (A2LA), published a policy in 2012 stating that higher measurement uncertainties are expected from onsite calibration. View that policy here: A2LA Policy P104
Accuracy & Precision is important when I use my multichannel pipette, what calibration plan would you recommend?
We recommend adding individual channel calibration for your multichannel pipette if you need each channel to be precise and accurate (such as when preforming RT-PCR, ELISA, ECL and Bioassays). This means each channel is individually adjusted, weighed, and calibrated. To add this to any pipette calibration service, check the box for “Multi-Channel Readings (per channel) on the “Pipette Service Order Form”
How much does it cost to fix my broken pipette?
We provide free repair estimates once the broken pipette is in our calibration facility. We only charge you for pipette calibration and replacement parts.
How long does Calibration take?
We offer complimentary 2 Business Day turn-around time to our customers, to request this option check the box “48 HOUR SERVICE” on the Pipette Service Order Form. You can also request 1 business day calibration by marking the box “24 HOUR SERVICE” on the Pipette Service Order Form.